last maintenance | Gate | PROBLEMS FOUND | RESOLUTION |
---|---|---|---|
11/18/2023 | 1- (entry) | ||
11/18/2023 | 2- (exit) | ||
12/23/2023 | 1- (entry) | ||
01/14/2024 | 2- (exit) | ||
12/23/2023 | 2- (exit) | ||
01/14/2024 | 1- (entry) | ||
02/03/2024 | 1- (entry) | ||
02/03/2024 | 2- (exit) | ||
03/09/2024 | 1- (entry) | ||
03/09/2024 | 2- (exit) | ||
04/21/2024 | 1- (entry) | ||
04/21/2024 | 2- (exit) | ||
01/04/2025 | 1- (entry) |
1-Unauthorized person trying to fix the keypad. see(20250104_094737) 2-Battery issues. 3-KeyPad Voltage issues(Since the batteries are not in good condition, the current that feeds the system is below the voltage for the keypad to work, for now connect the Keypad directly to AC) 4-Pedestal is not properly attached to the ground. see(20250104_101105) |
1- Notify administration so that non-certified personnel do not try to fix the controller. 2-The batteries need to be replaced, there are two for each motor, please review the estimate. 3-Replace batteries 4-Use some type of cement to ensure that it does not move sideways as it could affect the wiring that connects the terminal to the motor. |
01/04/2025 | 2- (exit) |
1-Unauthorized person open the controller box, one screw is missing from the cover. see(20250104_102040). 2-Right gate section alignment. 3-Battery issues. 4-Arm (slave) over voltage detected on motor due to force applied by right gate section. |
1-Notify administration so that non-certified personnel do not try to fix the controller. 2-Alignment completed. see(20250104_102510) 3-The batteries need to be replaced, there are two for each motor, please review the estimate. 4-Updated the controller firmware to give the right “slave” arm more power to move the right section of the gate.(This is temporary) see(force reducer). INV-I250104551 |
01/04/2025 | Camera System |
1- HDD issue see(E250105552) |
1- Change the HDD |
03/29/2025 | 1- (entry) | ||
03/29/2025 | 2- (exit) | ||
03/31/2025 | Camera System |
NVR rec module defective |
New NVR |